Strong Waste Incinerators

The Professional will supply a Cremation System bundle for 2 (02) Cremators as well as system licensed by associated authority, which need to fit the alloted area as shown on the strategy drawings. As a result of the monetary condition in Bulgaria presently, our researches programs that a 100kg/hour system can fit the demands established …

Medical Waste treatment system

Medical Waste therapy system The medical waste therapy system will certainly be environmentally-friendly, as well as have a capability of relating to 200-300kg per set, to allow therapy of medical waste developed in a 160-bed medical center If, the equipment requires to be self-steam creating vapor is needed for the sanitation treatment. – Steel things. …

clinical waste burner

Australian burning style exclusive 5 25kg/hour double chamber( LPG) burner or equal approved. burner casing to be light steel with 125mm refractory lining containing essential and second chamber, protected draft area above second chamber, bundle burners, electronic temperature level control systems, ash rake as well as poke, 2nd door in main chamber, hands-on filling chute, …

incinerator, medical incinerator, small incinerator,waste incinerators”

Nanjing Clover Medical Technology Co., Ltd.  is a leading waste incinerator manufacturer in China. We are local  manufacturer and one of the largest exporter of China. Pyrolytic incinerator equipment technical is main waste treatment all of the world, for Medical Waste, Animal Incineration, Pet cremation and other Solid wste. The capacity from 10kgs/Hr. to 500kgs/Hr., …

Oil fired incinerator,Medical Waste Incinerator”

Medical Waste Incinerator   Items/Model TS100(PLC) Burn Rate Average 100 kg/hour Feed Capacity Average 200 kg/feed Control Mode PLC Combustion Chamber 1200L Internal Dimensions 120x100x100cm Secondary Chamber 600L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.7Kw Oil Consumption (kg/hour) 14–28 Gas Consumption (m3/hour) 10–32.2 Temperature Monitor Yes Temperature Protection Yes Oil Tank …

Hot sale small waste incinerators 30kgs and 50kgs per hour”

Items/Model TS30(PLC) TS50(PLC) Burn Rate 30 kg/hour 50 kg/hour Feed Capacity 60kg 100kg Control Mode PLC PLC Combustion Chamber 330L 560L Internal Dimensions 75x75x60cm 100x80x70cm Secondary Chamber 180L 280L Smoke Filter Chamber Yes Yes Feed Mode Manual Manual Voltage 220V 220V Power 0.5Kw 0.7Kw Oil Consumption (kg/hour) 10.2–20 12.1–24 Gas Consumption (m3/hour) 9.8–20 9.9–26.1 Temperature …

General waste incinerator with automated feeding system

a. be based on common, well-proven and clean technology – both as a complete unit and in terms of its individual components.  b. be very robust, sturdy and capable of installation in remote locations subject to severe conditions.  solid waste incinerator for medical waste disposal china incinerators Principle Medical Waste Incineration Treatment Burn Rate Average 1000-1500 kg/hour Feed Capacity Average 6000kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 4800Liter  Internal Dimensions 400*120*100 cm d. generate residual incinerator ash conforming to 

Industrial hazardous and nonhazardous waste and medical infectious waste

Industrial hazardous and nonhazardous waste and medical infectious waste   Incinerator Items/Model HICLOVER TS500(PLC) HICLOVER TS300(PLC) Burn Rate (Average) 500-600 kg/hour 300-500 kg/hour Feed Capacity(Average) 600kg/feeding 400kg/feeding Control Mode PLC Automatic PLC Automatic Primary Combustion Chamber 3000Liters(3.0m3) 2000Liters(2.0m3) Internal Dimensions 2100x1200x1200mm 1700x1200x1000mm Secondary Chamber 1500Liters(1.5m3) 1000Liters(1.0m3) Smoke Filter Chamber Yes Yes Feed Mode Manual Manual   Type of industries: Food processing units, beverages, Milk processing plants. Incineration per day requirement: 300 to 500 Kg per hour capacity. Loading: Automated continuous conveyor loading system. No. of chambers: primary, Secondary and Tertiary chambers are required. Treatment of gasses: scrubbing preferably dry type. Water treatment: In case if you supply system with wet scrubbing unit. Plc integration of all Temp, pressure, flu gas and residence time. …

Vertical closed incinerator combustion chamber

Medical waste, disposable syringes, infusion sets processing, cotton yarn, the operating room, the residual limb, waste rubber gloves,  protective clothing and infectious and harm venereal hospital bed supplies, general wastes.   Incinerator Items/Model HICLOVER YD300(PLC) HICLOVER YD500(PLC) Burn Rate (Average) 300-500 kg/hour 500-600 kg/hour Feed Capacity(Average) 480kg/feeding 800kg/feeding Control Mode PLC Automatic PLC Automatic Primary Combustion Chamber 2400L(2.4M3) 4000L(4.0M3) Internal Dimensions 220x110x100cm 257x147x108cm Secondary Chamber 1200L 1500L Smoke Filter Chamber Yes Yes Feed Mode Manual Manual Voltage 220V 220V   Burning temperature First combustion chamber: 800- 900 ℃ ; Secondary combustion chamber:2000℃ Flue gas residence time≥1s …