Author: bcepe

medical incinerator primary combustion price

Equipped with main combustion  chamber and a second chamber  for reburning  designed to ensure  complete combustion  of the gases  resulting  from  incomplete  combustion  of inert gases in the chimney, within the standards recommended  by the World Health Organization;   Equipped with temperature controller to adjust the air of the combustion of the waste, and fuel …

animal cremation equipment prices

    The following requirements are to be considered as an integral part of the technical specifications for each equipment type.   The system offered shall be designed to operate normally under the conditions of different regions in Kenya. These conditions may include but not limited to power supply, temperature, humidity, and other climatic conditions. …

medical incinerator design

It is expected that the Bidder will cooperate closely with PATH and target Hospitals for the new waste handling building/area and will make available all needed technical information, drawings, etc.,   The following waste streams shall be treated in the new HCW treatment center(s):   Infectious waste   Sharps waste   Pathological waste   Pharmaceutical …

hospital incinerator manufacturers

SECTION V   TECHNICAL SPECIFICATIONS OF THE INCINERATOR   General Description   The plant must have four distinct sections that demonstrate three principles of turbulence, residence time and temperature retention. The regulated sections may include but not limited to:   Overall plant layout Feed chamber/charging Primary combustion chamber Particulate scrubbers Acid gas The stack/chimney. Minimum …

pet crematorium equipment

Finally, steam to  the jacket should shut off, the unloading door is to be opened Then the shaft and mixing arms are reversed to act as unloading mechanism and should scoop the waste fragments out of the unloading door, onto a conveyor belt or directly into a waste container. The vessel should now be ready …

small incinerator for sale

Sterilization time: approx. 30 minutes at 121◦C/1.1 Bar or approx  15 minutes at 132◦C/2.5 Bar to achieve 6log10 sterility Fragmentation inside the chamber: Heavy duty with maximum size of final product <20 cm. Volume reduction of the waste after processing : by 60-80% through complete waste dehydration including liquid content of the waste All actions …

HEATER For incineration of Lab wastes products

Incinerators to be appropriate for the expert disposal of clinical & & & & medical waste/ rubbish with a better lots capability in the collection of about 1000-1500 Kg. The tough, self-contained burners will offer a exceptionally effective and effective, secure disposal in addition to be made according to appropriate globally directions, e.g. CE, EU, …

incinerator for medical waste

Lifting Chains: Must be dual lifting chain of roller style & must meet safety factor at least 6:1. Hydraulic System: Durable cylinder with a chrome plated ram and a relief valve for overload protection Forks: Heavy duty steel approx. 4.0” wide x 42” long fixed forks Platform: solid steel Battery: A heavy duty 12 volt, …

incinerator 500kg per hr

The secondary combustion chamber must destroy the contaminant product and must resist to high temperature(1100 °C)   Process Filtering system: Scruber to be mentionned as optional Emission Standards Compliance: BS 3316 or équivalent standard Version , the entire carcass of animals ( cattle , horses , Sheep, pigs , etc.) , as well as biologically …

red bag waste incinerator

“Waste chamber Chamber capacity 300 kg Chamber volume .54m3 Chamber size (outside) Width: 91cm, Height: 86cm Length: 152cm Door opening 66 x 76 cm Height to door 84 cm Height to top of stack 5.4 m Suggested slab size (L x W x Thickness) 1.8 m x 2.4 m x 10 cm Burn rate: Approximately …

medi burn 30 contraband incinerator

air retention for at least 2 seconds at a temperature of less than 850C, the combustion In order to achieve the proper effect. ? must be a two-chamber incinerators, primary and secondary Fuel stoves ? The waste products to reduce the initial volume Possible to minimize (approximately 5% sterile ash Form). Purpose: Top Loader incinerator …

medical small incinerator

Dimensions: World standard: 0.83m(I) x 1.0m(w) x 1.4m(h) Burning efficiency: >98% china double chamber incinerator Features: ?     Waste type and burn rate: Designed specifically for use by poultry farmers, game-keepers and for pet cremation. The incinerator will burn up to 50 kg of waste per hour. ?     Construction: Mild steel welded fabrication consisting of sheet …

hospital incinerator manufacturer

Up to 600kgs per ten-hour day of Type IV pathological waste or red bag waste rated at 2200 BTU’s per kg, based on batch loading twice daily. Incinerator, 20 kg/hr  Burn Capacity (min. 1200 kgs. Waste Feed Capacity per day) (4-6 hours operations) (Power Supply 380V, 50Hz, 3Ph) Capacity: 30 kg/hr. Number item: 01 unit …

medical waste heat value

18   Electrical supply required 3-phase 19   Auxiliary fuel      Diesel or paraffin 20   Primary burner 21 Secondary (after) burner 22 Type of burners   Automatic pressure jet 23   Output Primary   Approx 600 000 kJ/hour 24   Output Secondary      Approx 750 000kJ/hour 25 Emission control Heated refractory screen Low velocity grit arrester screen     Built in 26   Paint case     400 …

INCINERATOR DIESEL DRIVEN

BURNER, DIESEL DRIVEN waste kind: MEDICAL CARE WASTE Waste calorific well worth: 4000KCAL/KG Dampness Content: 10-25%. Small Capacity: 50Kg/Hour set tons. 2nd Chamber: 2 Secs @ 850degrees C. The major burning chamber have to ensure very little leave temperature degree is not less than 850 levels C. INSULATION. Calcium Silicate. Limiting Regular solution limit 1000 …

medical incinerators in china

Would plant operations be operational on a basis of 24 hours per day, 7 days a week, all year long except for regular and preventive maintenance periods?   How many hours per year could your process be operational?   What would be your approach for larger projects aiming to valorize 1 000 tons per day? …