Incinerator

Basic Info.

Model NO.:30 kg per hour
Pullution Sources:Solid Waste Processing
Processing Methods:Combustion
Export Markets:Global

Additional Info.

Trademark:clover

Product Description

Principle of the Incinerator equipment is incineration/combustion/burn. Generally, the function is waste treatment for Solid waste, Liquid waste, Gas waste, etc. 
The main body is one combustion chamber (at least), Refractory line or firebrick, Insulation materials and the outer plate. Ignition element is external oil or gas burner. The burner can be running until waste burnout but for some waste like plastic, paper (sometime, mix coal with waste before feeding), they can combustion itself after Ignition. During combustion, burner has a fan itself for Oxygen supply and also incinerator pet, incinerator pet a400, incinerator pet cremation, incinerator pet cremation prices, incinerator photo, incinerator plc controller, protect burner avoid heat damage from combustion chamber. And, there a external fan blow air into combustion chamber. The Exhaust gas blow out after combustion. 
Considering Environmental Protection requirements and rules, almost all incinerator have secondary combustion chamber (after-burn, post-combustion), even if third combustion chamber. The secondary burner burn the Exhaust gas from primary combustion chamber, this technology make sure sufficient combustion, few black smoke and smell. 
The updated incinerator technology focus on Exhaust gas treatment to remove Hazardous material and other function from incinerator, like heat recovery (waste to energy), save fuel cost, PLC Automation operation. 
In some Developed countries, some new waste treatment method like High-temperature cooking, waste carbonization, crushing sterilization technology is instead of incineration technology.

Items/Model TS30(PLC)
Burn Rate 30 kg/hour
Feed Capacity 60kg
Control Mode PLC
Combustion Chamber 330L
Internal Dimensions 75x75x60cm
Secondary Chamber 180L
Smoke Filter Chamber Yes
Feed Mode Manual
Voltage 220V
Power 0.5Kw
Oil Consumption (kg/hour) 10.2–20
Gas Consumption (m3/hour) 9.8–20
Temperature Monitor Yes
Temperature Protection Yes
Oil Tank 100L
Feed Door 55x50cm
Chimney 5Meter
Chimney Type Stainless Steel
1st. Chamber Temperature 800 degree –1000 degree
2nd. Chamber Temperature 1000 degree –1200 degree
Residency Time 2.0 Sec.
Gross Weight 3000kg
External Dimensions 175x120x140cm