Category: Blogs

General waste incinerator with automated feeding system

a. be based on common, well-proven and clean technology – both as a complete unit and in terms of its individual components.  b. be very robust, sturdy and capable of installation in remote locations subject to severe conditions.  solid waste incinerator for medical waste disposal china incinerators Principle Medical Waste Incineration Treatment Burn Rate Average 1000-1500 kg/hour Feed Capacity Average 6000kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 4800Liter  Internal Dimensions 400*120*100 cm d. generate residual incinerator ash conforming to 

Industrial hazardous and nonhazardous waste and medical infectious waste

Industrial hazardous and nonhazardous waste and medical infectious waste   Incinerator Items/Model HICLOVER TS500(PLC) HICLOVER TS300(PLC) Burn Rate (Average) 500-600 kg/hour 300-500 kg/hour Feed Capacity(Average) 600kg/feeding 400kg/feeding Control Mode PLC Automatic PLC Automatic Primary Combustion Chamber 3000Liters(3.0m3) 2000Liters(2.0m3) Internal Dimensions 2100x1200x1200mm 1700x1200x1000mm Secondary Chamber 1500Liters(1.5m3) 1000Liters(1.0m3) Smoke Filter Chamber Yes Yes Feed Mode Manual Manual   Type of industries: Food processing units, beverages, Milk processing plants. Incineration per day requirement: 300 to 500 Kg per hour capacity. Loading: Automated continuous conveyor loading system. No. of chambers: primary, Secondary and Tertiary chambers are required. Treatment of gasses: scrubbing preferably dry type. Water treatment: In case if you supply system with wet scrubbing unit. Plc integration of all Temp, pressure, flu gas and residence time. …

Vertical closed incinerator combustion chamber

Medical waste, disposable syringes, infusion sets processing, cotton yarn, the operating room, the residual limb, waste rubber gloves,  protective clothing and infectious and harm venereal hospital bed supplies, general wastes.   Incinerator Items/Model HICLOVER YD300(PLC) HICLOVER YD500(PLC) Burn Rate (Average) 300-500 kg/hour 500-600 kg/hour Feed Capacity(Average) 480kg/feeding 800kg/feeding Control Mode PLC Automatic PLC Automatic Primary Combustion Chamber 2400L(2.4M3) 4000L(4.0M3) Internal Dimensions 220x110x100cm 257x147x108cm Secondary Chamber 1200L 1500L Smoke Filter Chamber Yes Yes Feed Mode Manual Manual Voltage 220V 220V   Burning temperature First combustion chamber: 800- 900 ℃ ; Secondary combustion chamber:2000℃ Flue gas residence time≥1s …

Waste Incinerator Capacity average 30-50 kgs per hour

Waste Incinerator Capacity average 30-50 kgs per hour   Model YD-30C Main Product List   Primary Combustion Chamber     Secondary Combustion Chamber     Mix-Combustion Chamber     Smoke Filter Chamber     Incinerator Control Case (PLC Auto Type)     Chimney:5.0Meters *(upgrade to Stainless Steel, free cost)     Italy oil burner: 02 sets     Oil Tank: 200Liters     …

Incinerator Items/Model HICLOVER TS20(PLC)

Main Product List per 01 set Primary Combustion Chamber Secondary Combustion Chamber Smoke Filter Chamber Incinerator PLC Control Case Chimney:5.0Meters  *(upgrade to Stainless Steel, free cost) Italy oil burner: 02 units Oil Tank (if oil fuel): 200Liters Incinerator Items/Model HICLOVER TS20(PLC) Burn Rate (Average) 20-30 kg/hour Feed Capacity(Average) 40kg/feeding Control Mode PLC Automatic Primary Combustion Chamber 210L Internal Dimensions 65x65x50cm             Nanjing Clover Medical Technology Co.,Ltd. Ecolead Technology(Nanjing) Co.,Ltd. Mobile: +86-13813931455(WhatsApp) Website: www.hiclover.com  Email:     sales@hiclover.com  Email:     hicloversales@gmail.com       2023-04-09

HICLOVER TS300(PLC) PLC Automatic Waste Incinerator

Default: Side Feeding Door Optional: Front/Top Feeding Door,  Wet scrubber Incinerator Items/Model HICLOVER TS300(PLC)   Burn Rate (Average) 300 kg/hour Feed Capacity(Average) 400kg/feeding Control Mode PLC Automatic Primary Combustion Chamber 2000Liters(2.0m3) Internal Dimensions 1700x1200x1000mm Secondary Chamber 1000Liters(1.0m3)                 Nanjing Clover Medical Technology Co.,Ltd. Ecolead Technology(Nanjing) Co.,Ltd. Mobile: +86-13813931455(WhatsApp) Website: www.hiclover.com  Email:     sales@hiclover.com  Email:     hicloversales@gmail.com       2023-04-09

INDUSTRIAL WASTE INCINERATORS FOR ALL SITES

    Picture   Feeding Door Location Top/Side Loading Burn Rate (up to) 200-300 kg/hour Control Mode PLC Automatic Primary Combustion Chamber 2000L(2.0M3) Primary Combustion Chamber Internal Dimensions 2000x1200x850mm Secondary Combustion Chamber 1000L(1.0m3) Feed Mode Manual/forklift/crane ***forklift/crane supply by local     We are particularly interested in your range of mobile incinerators and would appreciate …

Medical waste incinerator Burning Rate 100kg/hr

Subject Medical waste incinerator Day Capacity 1000kg Waste Type Medical waste   https://www.hiclover.com/#!/Model-TS100-Medical-Waste-Incinerator-100-150kgs-per-hour-capacity/p/416001748/category=0   Description Brand Model Fuel Type Medical Incinerator HICLOVER TS100 Diesel Oil/Natural Gas *Primary combustion chamber *Secondary combustion chamber *Smoke filter chamber * Stainless Steel chimney *Auto PLC control system *Italy brand burner * Automatic Protection Operator(APO) *Heavy duty refractory chamber *Corundum …

Waste Incinerator YD500(PLC) and YD600(PLC)

Thermocouples (S type) Thermocouples Tube(Corundum ) PLC Recording Function 5mm Steel shell Window on feed door     Incinerator Items/Model HICLOVER YD500(PLC) HICLOVER YD600(PLC) Burn Rate (Average) 500-600 kg/hour 600-800 kg/hour Feed Capacity(Average) 800kg/feeding 11000kg/feeding Control Mode PLC Automatic PLC Automatic Primary Combustion Chamber 4000L(4.0M3) 5500L(5.5M3) Internal Dimensions 257x147x108cm 300x147x125cm Secondary Chamber 1500L 1500L Smoke Filter Chamber Yes Yes Feed Mode Manual Manual Voltage 220V 220V …

incinerator for hospital

1, Using fever of gasifying unites burning technology. It applied to burn various  kinds of medical waste, such as syringes, infusion set, disposable dressing, and also  small animal, some city waste, like paper, tree leaves. 2, Closed vacuum-wide operation, applicable to treat infectious medical waste and to prevent secondary pollution. 3, Whole design, easy to …

Repair hospital incinerator

1. Diesel primary & secondary burners with frequency of 50-60hz able to attain 8500-1200 C. 2. Blower motor/ventilation fan of 40-60 W, 110-230 V, 50 hz 3. Refractory layer per square meter. 4. Incinerator chimney segments. 5. Incinerator door gasket 6. Secondary & primary chamber thermocouples capable of measuring 12000C 7. 500 litres steel fuel tank. …

TS30 Model Waste Incinerators

Nanjing Clover Medical Technology Co., Ltd. is a leading waste incinerator manufacturer in China. We are local  manufacturer and one of the largest exporter of China. Pyrolytic incinerator equipment technical is main waste treatment all of the world, for Medical waste, Pet animal cremation and other Solid waste. The capacity from 10kgs/Hr. to 500kgs/Hr., up …

Municipal waste incinerator

General waste incinerator  – Medium Minimum Requirements: General waste incinerator Dual chamber -Medium General requirements,how to neutralize acidity in garbage incinerated waste “ Size and efficiency The proposed incinerator units must be complete and include all of the key features listed below and all of the associated support services and interconnectionsThe operator will proceed to …

CONTAINERIZED INCINERATOR

CONTAINERIZED INCINERATOR ELECTRIC POWER SUPPLY: (GHANI 220V-50HZ-3PH, AMAL 220V-60HZ-3PH, RAS LANUF 380V_400V – 50HZ- 3PH, TIBISTI 220V-60HZ-3PH, EN-NAGA 220V- 50/60HZ- 3PH).GENERAL : A CONTAINERIZED INCINERATOR WITH DESIGHN SUITABLE FOR USE IN REMOTE AREAS SPECIFICALLY OIL AND GAS INDUSTRY.INCINERATOR UNIT SHOULD BE ABLE TO HANDLE COMMON WASTE WITH ABILITY TO ACCEPT SMALL AMOUNTS OF MEDICAL WASTE, …

Secure Payments

We accepet Paypal payment online

Fixed Price after payment

The price is fixed after you payment

Delivery on EXW Factory Term

We delivery on EXW Factory Term. Shipping term is separated
Open chat