medi burn 30 contraband incinerator

air retention for at least 2 seconds at a temperature of less than 850C, the combustion

In order to achieve the proper effect.

? must be a two-chamber incinerators, primary and secondary

Fuel stoves

? The waste products to reduce the initial volume

Possible to minimize (approximately 5% sterile ash

Form).

Purpose: Top Loader incinerator of general, medical and dry waste to comply with the requirements of the Air Quality

Act, 2004 (Act No 39 of 2004)

 

1     Design standard  Retort type, multiple

2     Description of chimney     Top mounted, self supporting, unlined

3     Stack height from base     At least 11 meter (depends on height above sea level)

4     Incineration performance Capacity       750 kg/hour

5    Temperature Primary  Minimum 850 degree Celsius

6     Temperature Secondary    Minimum 1000 degree Celsius

7     Dimensions (minimum)(cm)

Length

Width

Height

210

180

210

8     Loading door opening (m)       200

9     Description of grate/hearth      Full

10   Primary chamber volume (minimum)     1.05 cubic meters

11   Tools included    Poker, hoe, rake

12   Materials of construction (minimum)

Case

Bracing

Hearth

 

 

 

Ashing door

Loading door

 

?     Chamber Volume: 0.1m3

?     Load method: Front

?     Fuel options: Diesel  or Natural gas

?     Typical fuel: Liquid propane gas: 6 liters per hour

?     Consumption: Natural gas: 6 liters per hour

Secure Payments

We accepet Paypal payment online

Fixed Price after payment

The price is fixed after you payment

Delivery on EXW Factory Term

We delivery on EXW Factory Term. Shipping term is separated